 Flush or surface mounted
Refuge occupied switch, which activates the refuge system
Listening facility at control panel
System in use & healthy indicators
Volt free contact, active when occupied. To operate over-door lamps etc.
 Red or stainless steel finish available
Dimensions: 134mm (W) x 134mm (H) x 46mm (D)
System Requirements:
Enhanced fire rated four core cable with drain must be used, Baldwin Boxall recommends colour coded.
Please contact our sales department for exact cable requirements
Up to 200m cable run between units as standard
A repeater unit must be used if distance between each remote unit exceeds 200m
A ring circuit configuration must be used
VIGIL CommuniCare utilises a ring circuit, which means up to sixteen remote units are on each ring with up to 200 metres between each unit as standard. It is possible to extend this distance between each remote unit by installing a repeater unit between the two remote units. It is necessary for the first and last remote units to be no more than 200 metres from the control panel. By utilising this ring method it is possible to save up to 75% on cabling costs when compared with typical star circuit systems. The intelligence of the system ensures that if the circuit were to be broken at any point on the loop, the system will still operate with no loss of communication.

|